Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
Adv Clin Exp Med ; 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38439611

RESUMO

Ceramic is a commonly used material in dentistry for reconstructing missing teeth or their tissues due to its biocompatibility, durability and excellent esthetic properties. Despite these advantages, the ceramic restoration damage remains a significant clinical problem. Its causes can be divided into clinical and laboratory factors. The most known include uneven occlusion, improper preparation, trauma, or parafunctions. This study focuses on characterizing less known laboratory causes of ceramic restoration damage. We reviewed the current literature available in the PubMed and Scopus databases. On the basis of 63 selected studies, 3 basic causes of damage were identified: excessive stresses between the framework and ceramic veneering, poor quality of the connection between the facing layer and the substructure, and defects resulting from the nature of the ceramic material such as defects in the ceramic layer, brittleness and lack of flexibility. The stages of the manufacturing process of various permanent ceramic restorations were presented. By controlling these procedures, we can eliminate the errors, resulting in long-term effective functioning of the ceramic restorations.

2.
Heliyon ; 10(3): e24950, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38317893

RESUMO

In dentistry, the shade selection of the restoration affects the success of the restoration. For this reason, it may be decisive for clinicians to determine whether the difference in framework production influences color in metal-ceramic restorations. The study examined the effects of different framework production techniques used in porcelain-fused-to-titanium restorations on color changes. 45 square-shaped samples were manufactured using cast, milling, and laser-sintering techniques. Opaque and dentin porcelain were performed, and all samples were glazed. A spectrophotometer was used for color measurements. Before opaque application, after opaque application, and after porcelain + glaze application, it was obtained L*, a*, and b* values. Color differences (ΔE00) were calculated with the CIEDE2000 formula. ANOVA (Post Hoc: Bonferroni) and Shapiro Wilks (Normality) tests were used for statistical analysis (p < 0.05). At the different laboratory steps, the difference between cast&laser-sintered groups and between milled&laser-sintered groups was statistically significant (p < 0.05). Before and after opaque application, the differences in L*, a*, and b* values between cast, milled, and laser-sintered groups were statistically significant (p < 0.05). Different framework production methods influenced the color of porcelain-fused-to-titanium restorations.

3.
Front Dent ; 20: 43, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38410504

RESUMO

Objectives: This study aimed to evaluate the shear bond strength (SBS) of two repair composites (Crea.lign vs. PermaFlo) to a base metal alloy and zirconia ceramic. Materials and Methods: Sixty-four discs (12mm diameter, 1mm thickness) were fabricated using Wirobond base metal alloy and zirconia. They were then bonded with their respective composite resins (N=16) in each of the two porcelain chipping repair kit subgroups consisting of PermaFlo and Crea.lign. All specimens were stored in 37°C distilled water for 24 hours. Half of them were subjected to 10,000 thermal cycles (5-55°C, 30s). All specimens were tested for SBS with a universal testing machine. Failure types were analyzed using a digital camera. Analysis of the data was done by two-way ANOVA and Bonferroni post-hoc tests. Results: SBS was significantly affected by the type of composite resin. PermaFlo had a significantly higher SBS than Crea.lign to base metal alloy (P<0.001) and zirconia ceramic (P<0.001). Thermocycling decreased the SBS of both composites to base metal alloy (P<0.001) and zirconia (P<0.001). Conclusion: A universal adhesive could provide higher shear bond strength of zirconia and base metal alloy to composite resin than Crea.lign composite and the MKZ primer supplied by its manufacturer.

4.
Braz. j. oral sci ; 21: e225136, jan.-dez. 2022. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1354771

RESUMO

Aim: To evaluate the influence of cobalt-chromium (Co-Cr) coping fabrication methods and ceramic application on the marginal and internal fit of metal-ceramic crowns. Methods: Co-Cr copings for metal-ceramic crowns were prepared by lost wax casting or CAD-CAM machining of sintered blocks. The fit was analyzed using the silicone replica technique at four assessment points: marginal gap (MG), axial wall (AW), axio-occlusal (AO) angle, and central occlusal (CO) wall. After the initial analysis, the copings were ceramic-veneered with the layering technique, and the fit was again determined. Data were statistically analyzed by paired and unpaired Student's-t test (α=0.05). Results: Marginal and internal fit before ceramic application according to the coping manufacturing method showed significant differences only at CO (p < 0.001), with milled copings (137.98±16.71 µm) showing higher gap values than cast copings (112.86±8.57 µm). For cast copings, there were significant differences at MG (before 109.13±8.79 µm; after 102.78±7.18 µm) and CO (before 112.86±8.57 µm; after 104.07±10.63 µm) when comparing the fit before and after ceramic firing. For milled copings, there was significant difference only at AO (before 116.39±9.64 µm; after 108.54±9.26 µm). Conclusion: This study demonstrated that the coping fabrication method influenced the internal fit. Ceramic firing maintained or improved the fit of the metal-ceramic crowns. The marginal discrepancy of all restorations, before and after ceramic firing, can be considered clinically acceptable


Assuntos
Cerâmica , Ligas Metalo-Cerâmicas , Adaptação Marginal Dentária , Coroas
5.
Clin Exp Dent Res ; 8(3): 763-770, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35187813

RESUMO

OBJECTIVES: Restoration fit is one of the prerequisites of clinical durability. It is controversial as to whether computer-assisted design/computer-aided milling (CAD/CAM) or lost-wax fabrication methods result in more fit metal-ceramic crowns. This in-vitro study was conducted to examine the internal fit of porcelain fused to metal crowns fabricated using CAD/CAM and lost-wax techniques during fabrication stages (framework, porcelain, cementation) through digital triple scanning, replica weighting, and observation with electron microscopy. MATERIAL AND METHODS: Twenty uniform resin dies of prepared first maxillary molars were randomly divided into two groups according to the fabrication technique: lost wax and CAD/CAM. The internal fit was measured in all steps of completing the crowns (framework, porcelain, and cementation) using different methods, including triple scanning, replica weighting, and scanning electron microscopy. The data were statistically analyzed using t test, Pearson, and repeated measures analysis of variance (α = .05). RESULTS: Triple scanning revealed no difference in the internal fit of CAD/CAM and lost-wax groups in all the fabrication steps (p > .05). The replica weighting method showed no difference between groups in the framework step (p > .05), while the internal fit was significantly better in the CAD/CAM group after porcelain application (p < .05). After cementation, electron microscopy measurements showed no difference between CAD/CAM and lost wax groups (p > .05). The Pearson correlation test showed no significant correlation between electron microscopy, replica weighing, and triple scanning methods (p > .05). CONCLUSION: According to scanning electron microscopy as the superior evaluation method, the internal fit of cobalt-chrome PFM crown of both CAD/CAM and lost wax groups was within the acceptable clinical range and there was no significant difference between them. Triple scanning revealed no difference in the internal fit of framework and porcelain steps but a better fit after cementation. According to replica weighting, the internal fit in the porcelain step was higher than the framework.


Assuntos
Adaptação Marginal Dentária , Porcelana Dentária , Desenho Assistido por Computador , Coroas , Planejamento de Prótese Dentária/métodos , Microscopia Eletrônica de Varredura
6.
Gen Dent ; 70(1): 30-33, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34978987

RESUMO

The purpose of this in vitro study was to compare the 3- and 90-day bond strengths of 3 cements used for luting metal-ceramic crowns. Zinc phosphate cement (ZPC; SS White), resin-modified glass ionomer cement (RMGIC; Fuji Plus), and self-adhesive resin cement (SARC; RelyX U200) were assessed in 2 different treatment conditions (with and without microsandblasting of the alloy) and at 2 experimental times (3 days [E1] and 90 days [E2] after cementation). The buccal surfaces of 84 bovine teeth were ground until the dentin was exposed, and 84 nickel-chromium alloy plates cast from a resin model were cemented to the dentin surfaces with 1 of the 3 cements (n = 28). In half of the specimens of each group (n = 14), the bonding surfaces of the nickel-chromium plates received 6 seconds of microsandblasting with 45-µm aluminum oxide particles prior to cementation. The compressive shear bond strengths of the specimens were evaluated in a universal testing machine at E1 and E2 (n = 7). The SARC group showed the greatest bond strength, followed by the RMGIC group, while the bond strength of the ZPC group was significantly lower (P < 0.01). For the RMGIC specimens subjected to microsandblasting, there was a statistically significant difference between the mean bond strengths at E1 and E2 (P = 0.040). All of the other cement and treatment groups showed statistically similar adhesion results at E1 and E2 (P > 0.05). The complementary test by Sidák revealed that the cements Fuji Plus and RelyX U200 showed higher values at E2 and were statistically similar to each other (P > 0.05). Although RMGIC specimens showed a lower initial bond strength than SARC specimens, the fact that the microsandblasted RMGIC subgroup was the only one that demonstrated a significant increase in bond strength with aging suggests that RMGIC can be a material of first choice because it also costs less than SARC.


Assuntos
Colagem Dentária , Animais , Bovinos , Ligas de Cromo , Cimentos Dentários/uso terapêutico , Análise do Estresse Dentário , Cimentos de Ionômeros de Vidro , Humanos , Teste de Materiais , Cimentos de Resina , Propriedades de Superfície
7.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1385780

RESUMO

ABSTRACT: The present study aims to describe through a literature review, the main types of noble and non-noble alloys in dentistry looking to identify the adhesion mechanisms, compositions and mechanical properties, and its applicability as a rehabilitation resource nowadays. A bibliographic search was conducted in the main health databases PUBMED (www.pubmed.gov) and Scholar Google (www.scholar.google.com.br), in which studies published from 1971 to 2021 were collected. Laboratory studies, case reports, systematic and literature reviews, which were developed in living individuals. Articles that did not deal with metal alloys and its use in dentistry were excluded. Through the review, it was possible to ver ify that all works presented the metal alloys and their main properties, indicating that they are divided into three main types: hi gh noble alloys, noble alloys and base metal alloys differing in their levels of constituent noble metals. Several alloys and meta ls are available for the dental market each presenting advantages and disadvantages, mainly based on its specific composition.Continuous research and development are resulting in the production of new technologies and products, giving dental surgeons even more options in the design and manufacture of restorations using metal alloys and understanding that these resources will still be viable alternatives in oral rehabilitations. However, further studies on metal alloys are needed to better understand this subject.


RESUMEN: El presente trabajo tuvo como objetivo describir a través de una revisión de la literatura, los principales tipos de aleaciones nobles y no nobles utilizados en odontología buscando identificar los mecanismos de adhesión, composiciones y propiedades mecánicas, así como reflejar su aplicabilidad como recurso rehabilitador en la actualidad. Realizamos una búsqueda bibliográfica em las principales bases de datos de salud PUBMED (www.pubmed.gov) y Scholar Google (www.scholar.google.com.br), en la que se recopilaron estudios publicados desde 1971 hasta 2021. Estudios de laboratorio, informes de casos, revisiones sistemáticas y bibliográficas, que se desarrollaron en individuos vivos. Sin embargo, se excluyeron los artículos que no trataban sobre aleaciones metálicas y su uso en odontología. Se pudo observar que todos los trabajos presentaban las aleaciones metálicas y sus principales propiedades indicando que se estas dividen en tres tipos principales: aleaciones altamente nobles, aleaciones nobles y aleaciones de metales base que difierenen sus niveles de metales nobles constituyentes. Hay varias aleaciones y metales disponibles para el mercado dental, cada uno presenta ventajas y desventajas, principalmente en función de su composición específica. La investigación y el desarrollo continuo están dando como resultado la producción de nuevas tecnologías y productos, brindando a los cirujanos dentistas aún más opciones en el diseño y fabricación de las restauraciones, utilizando aleaciones metálicas y, permite concluir que estos recursos seguirán siendo alternativas viables en los tratamientos de rehabilitación. Sin embargo, se necesitan más estudios sobre el tema abordado en el trabajo, para una comprensión más profunda del tema.

8.
Dentomaxillofac Radiol ; 50(3): 20200134, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-32941742

RESUMO

OBJECTIVES: To evaluate, in an in vitro study, the quantity of artefacts generated by two different restorative materials, and to determine the diagnostic accuracy of cone beam CT (CBCT) scans and periapical radiographs in identifying gaps in prosthetic crowns. METHODS: A total of 30 teeth restored with metal-ceramic (n = 15) and all-ceramic (n = 15) crowns, properly adapted and with 0.30- and 0.50 mm gaps, underwent CBCT exams (with voxel sizes of 0.25 and 0.30 mm) and periapical radiographs. The artefacts generated by two different crowns were quantified and compared by the Mann-Whitney test. In addition, five examiners evaluated the presence or absence of gaps in periapical radiographs and CBCT images. The accuracy of tests was determined by the area under the receiver operatring characteristic curve and these values were compared by using the Kruskal-Wallis test. RESULTS: There was no significant difference in artefact values between the different restorative materials and the different resolutions of CBCT images. Regarding the accuracy of the tests evaluated, periapical radiography and CBCT with voxel size 0.25 mm showed the best performance for smaller gaps (0.30 mm). For larger gaps (0.50 mm), all exams tested showed the same performance. CONCLUSIONS: Periapical radiography was still the most cost-beneficial method for the diagnosis of maladaptation in dental restorations. CBCT exams did not improve accuracy in detecting gaps in prosthetic crowns.


Assuntos
Tomografia Computadorizada de Feixe Cônico Espiral , Fraturas dos Dentes , Artefatos , Tomografia Computadorizada de Feixe Cônico , Coroas , Humanos
9.
J Am Dent Assoc ; 151(4): 230-238.e7, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32222175

RESUMO

BACKGROUND: The authors aimed to compare the survival and complication rates of zirconia-ceramic (ZC) versus metal-ceramic (MC) restorative material in multiunit tooth-supported posterior fixed dental prostheses (FDP). TYPES OF STUDIES REVIEWED: The authors conducted a systematic search of randomized controlled trials (RCTs), with no time or language restrictions, up to May 2019 using the MEDLINE (PubMed), Scopus, Web of Science, and Cochrane Central Register of Controlled Trials databases, followed by a manual search. RESULTS: The authors included 7 RCTs in the review and 5 RCTs in the meta-analysis. All studies had a low risk of bias. The authors included 330 participants (177 ZC and 173 MC tooth-supported FDP) in the meta-analysis, which revealed a medium-term survival rate of 95.4% (95% confidence interval [CI], 90.5% to 99.1%) for ZC FDP compared with 96.9% (95% CI, 94.3% to 99.4%) for MC FDP, with no significant differences (P = .364). The biological or technical complications did not show statistically significant differences, except in the global ceramic veneering chipping analysis (P = .023; risk difference [RD], 22.3%; 95% CI, 3.0% to 41.6%) and their subanalysis: minor chipping or chipping that can be solved with polishing (P = .044; RD, 19.5%; 95% CI, 0.5% to 38.4%), and major chipping or chipping that needs repair in the laboratory (P = .023; RD, 6.0%; 95% CI, 0.8% to 11.3%). CONCLUSIONS AND PRACTICAL IMPLICATIONS: Posterior multiunit ZC restorations are considered a predictable treatment in the medium term, although they are slightly more susceptible to chipping of the veneering ceramic than MC restorations.


Assuntos
Planejamento de Prótese Dentária , Falha de Restauração Dentária , Prótese Parcial Fixa , Cerâmica , Porcelana Dentária , Ligas Metalo-Cerâmicas , Ensaios Clínicos Controlados Aleatórios como Assunto , Zircônio
10.
J Orthop Surg Res ; 15(1): 90, 2020 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-32131862

RESUMO

BACKGROUND: Orthopedic metal implants are notoriously associated with release of metallic ions able to cause biological adverse reactions which might lead to implant loosening and failure. To limit any possible adverse reactions, ceramic coatings for orthopedic metal implants have been introduced. However, information regarding the interaction of these coatings with microbes responsible for periprosthetic joint infections (PJIs) is lacking. Hence, the aim of the present in vitro study is to assess the microbial affinity to a titanium-niobium nitride (TiNbN) coating. METHODS: Adhesion and biofilm formation of clinical isolates of Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, and Cutibacterium acnes were assessed on TiNbN-coated titanium discs in comparison with uncoated titanium and cobalt-chrome alloys discs, with either smooth or rough surfaces. Bacterial adhesion was performed by counting adhered bacteria in the first hours of incubation, and the biofilm formation was performed by means of a spectrophotometric assay and by confocal laser scan microscopy after 72 hours of incubation. RESULTS: Overall, Staphylococcus aureus and Staphylococcus epidermidis, among the most common bacteria responsible for PJIs, displayed a significantly decreased attachment in the first hours of contact and, when cultured in presence of TiNbN coating, in comparison with CoCrMo. Biofilm formation of the four tested strains was comparable on all alloys. CONCLUSIONS: Although the onset of a PJI is more complex than in an in vitro scenario, these findings suggest that TiNbN-coated orthopedic implants do not increase PJIs risk while ameliorating tribological and surface properties could represent a valid choice to limit possible complications such as metal hypersensitivity.


Assuntos
Ligas/administração & dosagem , Aderência Bacteriana/fisiologia , Materiais Biocompatíveis/administração & dosagem , Biofilmes/crescimento & desenvolvimento , Infecções Relacionadas à Prótese/patologia , Infecções Estafilocócicas/patologia , Cerâmica/uso terapêutico , Humanos , Microscopia Confocal/métodos , Propionibacteriaceae/crescimento & desenvolvimento , Propionibacteriaceae/isolamento & purificação , Infecções Relacionadas à Prótese/prevenção & controle , Pseudomonas aeruginosa/crescimento & desenvolvimento , Pseudomonas aeruginosa/isolamento & purificação , Infecções Estafilocócicas/prevenção & controle , Staphylococcus aureus/crescimento & desenvolvimento , Staphylococcus aureus/isolamento & purificação , Staphylococcus epidermidis/crescimento & desenvolvimento , Staphylococcus epidermidis/isolamento & purificação
11.
Biomater Investig Dent ; 7(1): 41-49, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32128510

RESUMO

Purpose: Even though the use of full ceramic crowns have become a well-established practice in dental clinics compare to the last decade, the use of imported casted porcelain-fused-to-metal (PFMs) crowns is still prevalent. The use of imported PFMs is often economically driven; however, when dentists order PFMs, they do not have capabilities to examine its true alloy content. Therefore, we raise the questions whether cheaper imported PFMs have more discrepancies in alloy content compared to domestically produced PFMs? Materials and Methods: This study included 62 porcelain-fused-to-metal crowns: 41 produced in Norway and 21 imported. Their alloy-composition was determined non-destructively by EDX and SEM. Results and Conclusions: Imported PFMs demonstrated larger deviations compared with non-imported PFMs. Significant deviation was found in key metallic elements in the different alloys (W, In, Pd, Ag). The detected deviations in key element such as Wolfram and Indium could influence the PFMs service time. These finding may be of international concern.

12.
Dent Med Probl ; 57(4): 417-422, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33444489

RESUMO

BACKGROUND: Computer-aided design/computer-aided manufacturing (CAD/CAM) systems are widely used for the fabrication of porcelain-fused-to-metal (PFM) crowns. OBJECTIVES: This study was conducted to compare PFM crowns through triple scanning in terms of marginal discrepancy between the CAD/CAM and lost-wax fabrication techniques. MATERIAL AND METHODS: Twenty uniform resin dies of a prepared maxillary first molar were randomly divided into 2 groups: conventional lost-wax; and milling. Marginal discrepancy was evaluated at the framework and porcelain steps through triple scanning and direct visualization under a stereomicroscope. Then, the crowns were cemented to the related die and the marginal gap was measured with triple scanning, direct visualization under a stereomicroscope and scanning electron microscopy (SEM). The data was analyzed using the independent t test and the one-way analysis of variance (ANOVA). The significance level was set at 0.05. RESULTS: Differences in the mean marginal gap were measured by the various evaluation methods. Triple scanning and stereomicroscopy identified increasing discrepancy during the fabrication process. According to the results of the independent t test, stereomicroscopy showed no difference after cementation between the CAD/CAM and lost-wax groups (p > 0.05), triple scanning showed higher fitness in the CAD/CAM group (p < 0.05), and SEM showed better adaptation in the lost-wax group (p < 0.05); however, there was a positive correlation between the findings of stereomicroscopy and SEM (p < 0.05). CONCLUSIONS: The cobalt-chromium crowns had clinically acceptable marginal fitness from both the CAD/CAM and lost-wax techniques; however, the lost-wax group showed lower marginal discrepancy after cementation according to SEM.


Assuntos
Adaptação Marginal Dentária , Planejamento de Prótese Dentária , Desenho Assistido por Computador , Coroas , Porcelana Dentária , Humanos
13.
J Contemp Dent Pract ; 21(8): 868-873, 2020 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-33568607

RESUMO

AIM: To compare fracture resistance between the cement-retained (CR), screw-retained (SR), and combined cement- and screw-retained (CCSR) metal-ceramic (MC) implant-supported molar restorations and the fracture mode after vertical loading simulation. MATERIALS AND METHODS: Thirty MC molar restorations were fabricated on thirty tilted dental implants that were repositioned using prefabricated or universal castable long abutments (UCLA) with 15° of angulation divided into three groups of ten specimens each. Group C: CR, group S: SR, and group CS: cement- and screw-retained. The crowns in group CS were adhesively bonded extraorally, and composite resin was used to fill the screw access holes (SAHs) in groups S and CS. Subsequently, all the specimens were tested for fracture resistance. A scanning electron microscope (SEM) evaluation of the fracture mode was also performed. Mean values of fracture loads were calculated and compared in Newtons (N) using one-way ANOVA and Tukey post hoc test (p < 0.05) for each group. RESULTS: Mean fracture load values were 2718.00 ± 266.25 N for group C, 2125.10 ± 293.82 N for group S, and 2508.00 ± 153.59 N for group CS. Significant differences were found between group S and the other groups on fracture load values. However, no significant differences were found between groups C and CS (p = 0.154). The failures were at MC framework interfaces on mesiolingual cusps. CONCLUSIONS: Cement and CCSR MC molar restorations showed comparable fracture resistance using abutments with 15° of angulation. However, SR design showed significantly the lowest values of resistance. Screw access hole did not significantly affect the fracture resistance of cemented MC molar restorations. All the specimens exhibited mixed adhesive fractures at the mesiolingual cusps. CLINICAL SIGNIFICANCE: Combined cement- and screw-retained restorations (CCSRRs) incorporate the simplicity of the cement method and the retrievability of the screw method, offering good resistance, allowing the removal of the excess of cement before clinical placement of the restoration, and providing another alternative for dental implant rehabilitation.


Assuntos
Falha de Restauração Dentária , Ligas Metalo-Cerâmicas , Parafusos Ósseos , Cerâmica , Coroas , Dente Suporte , Prótese Dentária Fixada por Implante , Análise do Estresse Dentário , Dente Molar
14.
Dent Res J (Isfahan) ; 16(5): 298-303, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31543935

RESUMO

BACKGROUND: The purpose of this study was to evaluate the bond strength between two porcelains (VITA VMK Master and VITA VM13) and two types of base metal alloys (Ceramill Sintron and Verabond). MATERIALS AND METHODS: In an experimental study, 20 rectangular strips (25 mm × 4 mm × 0.5 mm) of each base metal alloy (Ceramill Sintron and Verabond) were fabricated according to the manufacturer's instructions. After sandblasting and polishing, the samples were placed in an ultrasonic device to remove surface contaminants. A surface of 8 mm × 4 mm × 1 mm of samples was veneered with Vita VM13 and VITA VMK Master. The samples were divided into four groups (n = 10 each group; VM13/Ceramill, VMK Master/Ceramill, VM13/Verabond, and VMK Master/Verabond), and bond strength was evaluated by three-point bending test with a universal testing machine. Two-way ANOVA was used for comparison in each group, post hoc Scheffe's test was used for analyzing data between groups, and the Kolmogorov-Smirnov test was used for the normality (P < 0.05). RESULTS: The maximum bond strength was related to Verabond/VM13 (44.35 ± 7.9 MPa) and then the Ceramill Sintron/VM13 (39.33 ± 4.43 MPa), and the lowest was related to the Ceramill Sintron/VMK Master (29.75 ± 3.2 MPa). There was no significant difference between bond strength of VM13 with the two alloy groups (P > 0.05), and bond strength of VMK Master to Ceramill Sintron CAD/CAM alloy was less than the conventional Verabond alloy (P < 0.05); however, bond strength of all the groups was above the standard threshold (25 MPa). CONCLUSION: Based on the results of this study, the bond strength of the porcelain to Verabond was better, but the bond strength of the porcelain to Ceramill Sintron also was not less than the standard threshold; thus, this new CAD/CAM alloy can be an alternative to the conventional base metal alloys in the metal-ceramic restorations.

15.
RFO UPF ; 24(3): 422-428, 2019. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1357690

RESUMO

Objetivo: rizogênese incompleta refere-se a dentes permanentes em que não houve a formação completa do ápice radicular, ocasionando perda da vitalidade pulpar e, consequentemente, incapacidade da bainha epitelial de Hertwig para induzir a formação completa da raiz. Devido ao traumatismo e escurecimento dental, se faz necessário em certos casos a confecção de coroas em porcelana pura para reabilitar a paciente em estética e função. O presente trabalho tem como objetivo demonstrar um caso de reabilitação estética e funcional em dente com rizogênese incompleta, onde se consideraram as perdas estruturais e alteração de cor, para que seja possível estabelecer o tratamento mais adequado. Relato de caso: paciente de 16 anos, gênero feminino, atendida na Clínica de Odontologia de uma instituição privada, insatisfeita com a estética do seu dente devido ao escurecimento do elemento 21, pois quando tinha 5 anos o dente foi traumatizado juntamente com o elemento 11. O plano de tratamento adotado para ambos os elementos foi a confecção de peças protéticas em porcelana e cimentação. Considerações finais: esse caso demonstrou que a confecção de coroas estéticas em porcelana é considerada uma boa conduta na rotina clínica em casos de escurecimento dental, devolvendo estética e função para o paciente.(AU)


Objective: incomplete rhizogenesis refers to permanent teeth with incomplete formation of the root apex, causing loss of pulp vitality and the consequent inability of the Hertwig epithelial sheath to induce complete root formation. Due to dental trauma and darkening, some cases require the production of pure porcelain crowns to rehabilitate the aesthetics and function of patients. The present study aims to show a case of aesthetic and functional rehabilitation in a tooth with incomplete rhizogenesis, in which structural losses and color change were considered to establish the most appropriate treatment. Case report: a 16-year-old female patient treated at the Dental Clinic of a private institution. The patient was not satisfied with the aesthetics of her tooth due to the darkening of element 21, because at 5 years old the tooth was traumatized along with element 11. The treatment used for both elements was the production of prosthetic porcelain crowns and cementation. Final considerations: this case showed that the production of aesthetic porcelain crowns is considered a good conduct in the clinical routine in cases of tooth darkening, returning aesthetics and function to the patient.(AU)


Assuntos
Humanos , Feminino , Adolescente , Anormalidades Dentárias/terapia , Prótese Dentária/métodos , Traumatismos Dentários/terapia , Coroas , Resultado do Tratamento , Preparo Prostodôntico do Dente/métodos , Estética Dentária
16.
Zhonghua Kou Qiang Yi Xue Za Zhi ; 53(2): 141-144, 2018 Feb 09.
Artigo em Chinês | MEDLINE | ID: mdl-29429239

RESUMO

Cobalt-chromium alloys have been applied to dental porcelain fused to metal (PFM) restorations over the past decades owing to their excellent corrosion resistance, good biocompatibility and low price. The production of CoCr metal-ceramic restorations has always been based on traditional lost-wax casting techniques. However, in recent years, selective laser melting (SLM) is becoming more and more highly valued by dental laboratories and dental practitioners due to its individuation, precision and efficiency. This paper mainly reviews the recent researches on the production process of copings, microstructure, mechanical property, metal-ceramic bond strength, fit of copings, corrosion resistance and biocompatibility of SLM CoCr metal-ceramic alloy.


Assuntos
Ligas de Cromo , Técnica de Fundição Odontológica , Porcelana Dentária , Pesquisa em Odontologia , Terapia a Laser , Ligas Metalo-Cerâmicas , Cerâmica , Corrosão , Humanos
17.
Chinese Journal of Stomatology ; (12): 141-144, 2018.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-806029

RESUMO

Cobalt-chromium alloys have been applied to dental porcelain fused to metal (PFM) restorations over the past decades owing to their excellent corrosion resistance, good biocompatibility and low price. The production of CoCr metal-ceramic restorations has always been based on traditional lost-wax casting techniques. However, in recent years, selective laser melting (SLM) is becoming more and more highly valued by dental laboratories and dental practitioners due to its individuation, precision and efficiency. This paper mainly reviews the recent researches on the production process of copings, microstructure, mechanical property, metal-ceramic bond strength, fit of copings, corrosion resistance and biocompatibility of SLM CoCr metal-ceramic alloy.

18.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-701915

RESUMO

Objective To investigate the clinical effect of zirconia all -ceramic crown for anterior teeth restoration,and its influence on the quality of life .Methods Eighty-four patients with anterior teeth repair [4 cases were lost during the follow-up,and there were 80 cases (106 teeth)] were selected.According to different surgical methods,they were divided into control group (56 teeth) and study group (50 teeth).The control group used Ni Cr alloy porcelain crown,the study group used two zirconia all -ceramic crown.The patients were followed up for 1 year, the repair effect ,incidence rate of adverse reactions and quality of life score were compared between the two groups .Results After 1 year of crown restoration , the color, integrity, edge coloring in the study group were significantly better than those in the control group(all P<0.05).The incidence rate of adverse reactions such as gingivitis ,peri-odontitis,root fracture,allergies of the study group was 7.5%,which was significantly lower than 45.0%of the control group(χ2 =5.129,P<0.05).There were no statistically significant differences in quality of life scores between the two groups before repair(all P>0.05).The quality of life scores in the study group after repair were significantly higher than those in the control group (t=18.623,22.389,20.724,10.190,all P<0.05).Conclusion The clinical effect of zirconia all-ceramic crown for anterior teeth restoration is better .It can improve the aesthetic effect ,safety and quality of life score of patients .It is worthy of popularizing and application in clinic .

19.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-701697

RESUMO

Objective To compare the applicatied effect of two kinds of post core porcelain fused to metal crown for restoration of residual crown of first molar .Methods 52 patients with residual crowns of first molars (98 teeth) were selected.According to the random numerical table method ,they were divided into group A[post core crown of metal casting in 27 cases ( 49 teeth ) ] and group B [ post core crown of screw thread amalgam in 25 cases (49 teeth)].After a year of follow -up,the success rate of the two groups was compared .Results Metal casting core crown pile was broken at 0 in group A and at 3 in group B,the success rate of group A was 93.88%,and the success rate of group B was 79.59%,the difference was statistically significant between the two groups (χ2 =4.346, P<0.05).Conclusion The retention,resistance and durability of post core crown of metal casting is far superior to post core crown of screw thread amalgam ,and it is a more ideal repair method .

20.
J Dent Biomater ; 4(1): 367-372, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28959767

RESUMO

STATEMENT OF PROBLEM: Recent clinical results for Zirconia all-ceramic restorations have revealed that the fracture rate 6-15% of the Zirconia framework is so low and the core of Zirconia has high stability. However, chipping-off fractures of porcelain are the most common reason for failures of Zirconia in the fixed partial dentures. OBJECTIVES: The purpose of this study was to compare the shear bond strength (SBS) of porcelain in the porcelain fused to metal and all-ceramic crowns with Zirconia core. MATERIALS AND METHODS: Two groups were selected: porcelain fused to metal (PFM) and porcelain fused to Zirconia (PFZ) (n = 30).In the PFM group, a wax model (10 × 10 × 10mm)was used to cast metal base (Ni_Cr alloy). In the PFZ group, an acrylic cubic model (10 × 10 × 10mm) was made as Zirconia model for scanning.15 cubic Zirconia samples were milled by CAD-CAM. The procedure of porcelain veneering was conducted by the conventional layering technique up to 2 mm thickness (2.5 × 2.5 × 2 mm). All specimens were stored in water for 48 hrs. Thermal cycling was conducted for 20000 cycles between 55°C and 5ºC alternatively for 30s.All samples were mounted in acrylic resin and the SBS test was performed, using a universal testing machine. The analysis of data was performed at a significance level of 0.05 using Kolmogorov-Smirnov and Mann-Whitney U-test. RESULTS: Mean of SBS in PFM and PFZ was 24.57 and 20.88, respectively. The results of Mann-Whitney test showed that there was no statistically significant difference between the two groups of porcelain fused to metal and Zirconia in item shear bond strength (p = 0.455). CONCLUSIONS: There was no significant difference between the two groups of PFM and PFZ in the item SBS.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...